{"id":34811,"date":"2026-05-19T13:30:22","date_gmt":"2026-05-19T05:30:22","guid":{"rendered":"https:\/\/aiportek.com\/?p=34811"},"modified":"2026-05-19T13:30:27","modified_gmt":"2026-05-19T05:30:27","slug":"3d-camera-radiotherapy-patient-positioning-hongke","status":"publish","type":"post","link":"https:\/\/aiportek.com\/en\/3d-camera-radiotherapy-patient-positioning-hongke\/","title":{"rendered":"HONGKE Solution] 3D Camera Radiotherapy Positioning System - Sub-millimeter Surface Image Positioning"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"34811\" class=\"elementor elementor-34811\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-303a47ec elementor-section-stretched elementor-section-full_width elementor-section-height-min-height elementor-section-content-middle elementor-section-height-default elementor-section-items-middle\" data-id=\"303a47ec\" data-element_type=\"section\" data-settings=\"{&quot;stretch_section&quot;:&quot;section-stretched&quot;,&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-27d5e225\" data-id=\"27d5e225\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-4e369ae3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4e369ae3\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-6555484e\" data-id=\"6555484e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-397ef20e elementor-widget elementor-widget-heading\" data-id=\"397ef20e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hongke's latest articles<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b5c0d9b elementor-absolute elementor-widget elementor-widget-heading\" data-id=\"4b5c0d9b\" data-element_type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">HongKe<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6d18033c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6d18033c\" data-element_type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1f96cecf\" data-id=\"1f96cecf\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-fd50b9b elementor-widget elementor-widget-text-editor\" data-id=\"fd50b9b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d303089 elementor-widget elementor-widget-text-editor\" data-id=\"d303089\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-4b0e7b4e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4b0e7b4e\" data-element_type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-7a4b7cfc\" data-id=\"7a4b7cfc\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-79a3214 elementor-widget elementor-widget-heading\" data-id=\"79a3214\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">HONGKE Solution] Radiotherapy Vision Positioning Application Based on High Precision Binocular Spread Spectrum 3D Camera<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-226f412 elementor-widget elementor-widget-post-info\" data-id=\"226f412\" data-element_type=\"widget\" data-widget_type=\"post-info.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-inline-items elementor-icon-list-items elementor-post-info\">\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-2358f4d elementor-inline-item\" itemprop=\"author\">\n\t\t\t\t\t\t<a href=\"https:\/\/aiportek.com\/en\/author\/hongketechnology\/\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-far-user-circle\" viewbox=\"0 0 496 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M248 104c-53 0-96 43-96 96s43 96 96 96 96-43 96-96-43-96-96-96zm0 144c-26.5 0-48-21.5-48-48s21.5-48 48-48 48 21.5 48 48-21.5 48-48 48zm0-240C111 8 0 119 0 256s111 248 248 248 248-111 248-248S385 8 248 8zm0 448c-49.7 0-95.1-18.3-130.1-48.4 14.9-23 40.4-38.6 69.6-39.5 20.8 6.4 40.6 9.6 60.5 9.6s39.7-3.1 60.5-9.6c29.2 1 54.7 16.5 69.6 39.5-35 30.1-80.4 48.4-130.1 48.4zm162.7-84.1c-24.4-31.4-62.1-51.9-105.1-51.9-10.2 0-26 9.6-57.6 9.6-31.5 0-47.4-9.6-57.6-9.6-42.9 0-80.6 20.5-105.1 51.9C61.9 339.2 48 299.2 48 256c0-110.3 89.7-200 200-200s200 89.7 200 200c0 43.2-13.9 83.2-37.3 115.9z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-author\">\n\t\t\t\t\t\t\t\t\t\tHongKeTechnology\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t<\/li>\n\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-a689c23 elementor-inline-item\" itemprop=\"datePublished\">\n\t\t\t\t\t\t<a href=\"https:\/\/aiportek.com\/en\/2026\/05\/19\/\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-calendar\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M12 192h424c6.6 0 12 5.4 12 12v260c0 26.5-21.5 48-48 48H48c-26.5 0-48-21.5-48-48V204c0-6.6 5.4-12 12-12zm436-44v-36c0-26.5-21.5-48-48-48h-48V12c0-6.6-5.4-12-12-12h-40c-6.6 0-12 5.4-12 12v52H160V12c0-6.6-5.4-12-12-12h-40c-6.6 0-12 5.4-12 12v52H48C21.5 64 0 85.5 0 112v36c0 6.6 5.4 12 12 12h424c6.6 0 12-5.4 12-12z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-date\">\n\t\t\t\t\t\t\t\t\t\t<time>May 19, 2026<\/time>\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t<\/li>\n\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c027dd7 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"c027dd7\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a8309a elementor-widget elementor-widget-text-editor\" data-id=\"3a8309a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"143\" data-end=\"358\">In the field of radiation therapy (radiotherapy), millimeter-level errors can mean damage to healthy tissue or missed photos of tumor sites. With the increasing sophistication of radiotherapy technology, the need for clinical verification of patient position and real-time monitoring has reached an unprecedented level. Conventional optical surface imaging systems are facing challenges in terms of accuracy, interference resistance, and adaptability to complex surfaces. In this paper, we will discuss how HongKe's vision positioning system based on a high-precision binocular scatter 3D camera can revolutionize the radiotherapy positioning process and enhance the safety and efficacy of cancer treatment.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1943adf elementor-widget elementor-widget-heading\" data-id=\"1943adf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-small\">Clinical Pain Points: The \"Last Centimeter\" Problem of Precision Radiotherapy<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2016e7f elementor-widget elementor-widget-text-editor\" data-id=\"2016e7f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-path-to-node=\"5\">The core goal of radiation therapy (radiotherapy) is to deliver a high dose of radiation precisely to the tumor area while maximizing the protection of surrounding normal tissue. However, in the actual process of precision radiotherapy, the<b data-path-to-node=\"5\" data-index-in-node=\"63\">Positional management of patients<\/b>It became a critical bottleneck:<\/p><ol><li data-path-to-node=\"6,0,0\"><b data-path-to-node=\"6,0,0\" data-index-in-node=\"0\">The gap between planning and execution:<\/b>Although the treatment plan is based on advanced CT\/MRI images, it is often difficult to achieve a perfect match between the patient's actual position and the planned position during the actual treatment.<\/li><li data-path-to-node=\"6,1,0\"><b data-path-to-node=\"6,1,0\" data-index-in-node=\"0\">Offset between fractionated treatments:<\/b>During the cycle of multiple fractionated radiotherapy, the patient's weight change, body organ displacement and other variables will easily lead to inconsistency between the anterior and posterior body positions.<\/li><li data-path-to-node=\"6,2,0\"><b data-path-to-node=\"6,2,0\" data-index-in-node=\"0\">Micro-movements during treatment:<\/b>Even if the initial positioning is extremely precise, the patient's breathing, unconscious micromovements, or slippage can cause displacement of the target area during treatment.<\/li><li data-path-to-node=\"6,3,0\"><b data-path-to-node=\"6,3,0\" data-index-in-node=\"0\">Limitations of traditional methods:<\/b>Laser lights and skin marking points are highly dependent on the experience of medical personnel and have limited accuracy, while conventional surface optical systems are susceptible to interference from ambient light and less adaptable to complex surfaces.<\/li><\/ol><blockquote data-path-to-node=\"7\"><p data-path-to-node=\"7,0\"><b data-path-to-node=\"7,0\" data-index-in-node=\"0\">Adverse consequences:<\/b> Postural deviations can cause radiation dose distribution to deviate from the original plan, which in turn can reduce tumor control rates or significantly increase the risk of complications in normal tissue.<\/p><\/blockquote>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b46be3 elementor-widget elementor-widget-heading\" data-id=\"2b46be3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-small\">Technology: The Core Advantage of High-Precision Binocular Spotting 3D Camera<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fec9428 elementor-widget elementor-widget-text-editor\" data-id=\"fec9428\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-path-to-node=\"10\">With its unique imaging principle, binocular scattering 3D camera technology is an ideal solution for radiotherapy localization pain points. The core workflow of HongKe's solution is to actively project a high-density, high-contrast laser scatter pattern onto the target area, and two high-precision calibrated cameras simultaneously capture the surface-modulated scatter image from different angles. Finally, based on the triangulation principle and advanced stereo matching algorithm (utilizing the uniqueness of the scatter pattern), the system quickly calculates and generates high-density three-dimensional point cloud coordinates of the object surface.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d10f90 elementor-widget elementor-widget-image\" data-id=\"5d10f90\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"650\" src=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1024x650.jpg\" class=\"attachment-large size-large wp-image-34814\" alt=\"\" srcset=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1024x650.jpg 1024w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-300x191.jpg 300w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-768x488.jpg 768w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-18x12.jpg 18w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-600x381.jpg 600w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640.jpg 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-712f49e elementor-widget elementor-widget-heading\" data-id=\"712f49e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-small\">The technique has significant advantages for radiotherapy localization:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a046c3e elementor-widget elementor-widget-text-editor\" data-id=\"a046c3e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol><li data-path-to-node=\"12,0,0\"><b data-path-to-node=\"12,0,0\" data-index-in-node=\"0\">Superior precision and Robustness:<\/b>Its core value lies in its ability to provide sub-millimeter (typically better than 0.1mm @1m) high-precision surface point clouds, which are far more accurate than traditional optical methods, perfectly meeting the stringent millimeter positioning requirements of radiotherapy. At the same time, the active projection of the specific scatter pattern gives the system a strong anti-interference ability, which can effectively overcome the influence of complex ambient light in the operating room or treatment room (such as surgical shadowless lamps, treatment room lighting), to ensure stable and reliable operation in the real clinical environment.<\/li><li data-path-to-node=\"12,1,0\"><b data-path-to-node=\"12,1,0\" data-index-in-node=\"0\">Label-free, full-field, high-speed motion capture:<\/b>The system utilizes contactless measurements to obtain a complete three-dimensional view of the body surface without the need to stick skin markers on the patient's body. This not only avoids the cumbersome process brought about by additional operations, but also enhances patient comfort. The entire area of interest (e.g., chest, abdomen, head and neck) can be covered in a single shot, providing<b data-path-to-node=\"12,1,0\" data-index-in-node=\"115\">Up to 5 megapixel high resolution<\/b>The system is rich in detail. The maximum frame rate of the system is up to <b data-path-to-node=\"12,1,0\" data-index-in-node=\"144\">30fps<\/b>It is capable of real-time capture of breathing and other dynamic movements, realizing real-time three-dimensional imaging and providing strong support for dynamic monitoring during treatment.<\/li><li data-path-to-node=\"12,2,0\"><b data-path-to-node=\"12,2,0\" data-index-in-node=\"0\">Excellent surface adaptability:<\/b>The technology has excellent 3D reconstruction capability for complex and irregular surfaces such as skin and medical body molds, which can truly and completely reflect the patient's body shape information, effectively overcoming the limitations of traditional methods in surface reconstruction.<\/li><li data-path-to-node=\"12,3,0\"><b data-path-to-node=\"12,3,0\" data-index-in-node=\"0\">Provides free SDK for vision fusion of multiple 3D cameras:<\/b>When a project requires a large field of view coverage and a single camera's field of view is not enough to meet the demand, developers can use the multi-phase calibration fusion function integrated in the UI interface of the software to unify the field of view of multiple cameras under the same coordinate system, thus perfectly realizing the field of view expansion. This provides great convenience for medical equipment developers in application development.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63ee973 elementor-widget elementor-widget-heading\" data-id=\"63ee973\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-small\">System Construction: From 3D Data to Precise Positioning<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b5b4f2 elementor-widget elementor-widget-text-editor\" data-id=\"7b5b4f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-path-to-node=\"15\">Radiotherapy vision positioning systems based on binocular scatter 3D cameras have a clear architecture. The hardware core is a high-precision binocular scatter 3D camera module, which is usually mounted on a rack on either side or above the treatment bed, and its field of view needs to cover the patient's treatment area completely. Key performance indicators include accuracy, resolution, field of view (FOV), working distance and frame rate. The equipment needs to be crash and radiation resistant (or easily shielded) for safe integration into the radiotherapy room environment, with a high performance computing unit responsible for real-time data processing.<\/p><p data-path-to-node=\"16\">At the software level, the core point-and-cloud alignment algorithm is first performed<b data-path-to-node=\"16\" data-index-in-node=\"20\">Rigid alignment<\/b>The optimal spatial transformation (including translation and rotation deviations) between the current patient's body surface point cloud and the reference point cloud extracted from the outer surface of the planned CT image (or the reference surface model created at the time of the first treatment) is accurately calculated, which is the basis for the accurate reproduction of the \"planned body position\".<\/p><p data-path-to-node=\"17\">For more advanced clinical applications, the system can use<b data-path-to-node=\"17\" data-index-in-node=\"16\">Deformation Alignment Technology<\/b>The system is designed to handle non-rigid deformations due to respiration, organ motion, or weight changes to provide more detailed information about the displacement field. The system interface visually displays the translational (\u0394X, \u0394Y, \u0394Z) and rotational (Roll, Pitch, Yaw) deviations of the patient's current position from the reference position.<\/p><p data-path-to-node=\"18\">In addition, the safety monitoring and alarm function supports the setting of specific displacement thresholds to instantly monitor any patient movement during treatment. Once a displacement above the safety threshold is detected, the system triggers an audible and visual alarm and sends a signal to the gas pedal control system to pause the radiation exposure. The Data Management and Reporting Module automatically records positional error data before each treatment, movement trajectories during treatment, and generates standardized quality control (QC) reports to provide an objective basis for continuous improvement by the medical team.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7c3f17 elementor-widget elementor-widget-image\" data-id=\"f7c3f17\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-1024x576.webp\" class=\"attachment-large size-large wp-image-34815\" alt=\"\" srcset=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-1024x576.webp 1024w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-300x169.webp 300w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-768x432.webp 768w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-18x10.webp 18w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-600x337.webp 600w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6.webp 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Layout of Radiological Medical Body Positioning System<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-67df99e elementor-widget elementor-widget-image\" data-id=\"67df99e\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-1-1024x608.webp\" class=\"attachment-large size-large wp-image-34812\" alt=\"\" srcset=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-1-1024x608.webp 1024w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-1-300x178.webp 300w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-1-768x456.webp 768w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-1-18x12.webp 18w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-1-600x356.webp 600w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-1.webp 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Human Chest Positioning<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-774152d elementor-widget elementor-widget-image\" data-id=\"774152d\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-2-1-1024x683.webp\" class=\"attachment-large size-large wp-image-34813\" alt=\"\" srcset=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-2-1-1024x683.webp 1024w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-2-1-300x200.webp 300w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-2-1-768x512.webp 768w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-2-1-18x12.webp 18w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-2-1-600x400.webp 600w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-2-1.webp 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Three-dimensional localization of the human brain<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c521813 elementor-widget elementor-widget-heading\" data-id=\"c521813\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-small\">Typical application cases: practice in precision radiotherapy<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9688026 elementor-widget elementor-widget-text-editor\" data-id=\"9688026\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-path-to-node=\"24\">The radiotherapy center of a large oncology hospital introduced a vision positioning system based on binocular scatter 3D camera (core camera parameters: accuracy \u00b10.1mm @1m, FOV 900x866mm @1m), which was successfully applied to the position management of Nasopharyngeal Carcinoma Intensity-Modulated Radiation Therapy (IMRT) patients.<\/p><ul><li data-path-to-node=\"25,0,0\"><b data-path-to-node=\"25,0,0\" data-index-in-node=\"0\">The pendulum reference is established:<\/b> At the time of the patient's planned CT scan, a 3D camera is used simultaneously to capture point cloud data of the patient's body surface (face, neck) under immobilization devices (e.g., thermoplastic wrap + headrest), which is stored as a \"reference surface model\" in the Treatment Planning System (TPS).<\/li><li data-path-to-node=\"25,1,0\"><b data-path-to-node=\"25,1,0\" data-index-in-node=\"0\">Initial Precision Positioning:<\/b> Once the patient is lying on the treatment bed and immobilized, the laser lights in the radiotherapy room are used for initial positioning. The 3D visual localization system is then activated: the camera quickly takes a picture of the patient's current body surface and instantly reconstructs the point cloud. The rigid alignment of the current point cloud with the reference model in the TPS is accomplished within seconds. Based on the system's precise and quantitative guidelines, the medical staff can fine-tune the position of the treatment bed (translation and rotation) until all deviations are smaller than the preset thresholds (e.g. \u00b11mm \/ \u00b11\u00b0).<\/li><li data-path-to-node=\"25,2,0\"><b data-path-to-node=\"25,2,0\" data-index-in-node=\"0\">Treatment is monitored in real time:<\/b> During treatment beam (ray) irradiation, the system remains in continuous operation (in low dose mode or intermittent sampling) to monitor the patient's body surface position in real time. Once a displacement beyond the safety threshold is detected, an interlock mechanism is triggered to suspend the gas pedal irradiation and alert the healthcare personnel through an audible and visual alarm.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b5ec6e elementor-widget elementor-widget-heading\" data-id=\"5b5ec6e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-small\">Application Advantage Highlights:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fecdebd elementor-widget elementor-widget-text-editor\" data-id=\"fecdebd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol><li data-path-to-node=\"27,0,0\"><b data-path-to-node=\"27,0,0\" data-index-in-node=\"0\">Accuracy and efficiency are both improved:<\/b>With the assistance of the system, the final swing residual error can be stabilized at a very low level of &lt;1mm \/ &lt;1\u00b0, much better than the traditional swing method. The alignment calculation is fast and intuitive, and the adjustment process has a clear quantitative basis, so that the average swing time is shortened by about 40%.<\/li><li data-path-to-node=\"27,1,0\"><b data-path-to-node=\"27,1,0\" data-index-in-node=\"0\">The safety of the treatment is strongly guaranteed:<\/b>The real-time motion monitoring function can effectively capture unintentional patient movements (e.g. coughing, slight slipping) during treatment and prevent radiation dose distribution errors caused by positional deviations. Clinical records show that approximately 15% patients triggered a displacement alarm during a single treatment session, emphasizing the importance of this feature for clinical safety.<\/li><li data-path-to-node=\"27,2,0\"><b data-path-to-node=\"27,2,0\" data-index-in-node=\"0\">Well-established data management:<\/b>The system automatically records the positional error before each treatment and the maximum displacement data during the treatment process, providing a solid objective and quantitative basis for personalized treatment evaluation, optimized design of fixation devices and clinical academic research.<\/li><li data-path-to-node=\"27,3,0\"><b data-path-to-node=\"27,3,0\" data-index-in-node=\"0\">A better, more comfortable patient experience:<\/b>The label-free, non-invasive measurement greatly enhances patient comfort and compliance during radiation therapy.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7549dc6 elementor-widget elementor-widget-heading\" data-id=\"7549dc6\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-small\">V. Outlook and Conclusion<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e69fbf elementor-widget elementor-widget-text-editor\" data-id=\"0e69fbf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-path-to-node=\"30\">The high-precision binocular scatter 3D camera technology provides a revolutionary solution for body surface localization and monitoring in the field of radiation therapy. The technology combines the core advantages of non-contact, sub-millimeter high accuracy, strong interference resistance, and full-field high-speed dynamic measurement, effectively breaking through the bottleneck of traditional methods in terms of accuracy, efficiency, and reliability.<\/p><p data-path-to-node=\"31\">By deeply integrating into the whole process of radiotherapy, HongKe's system not only greatly improves the accuracy and efficiency of initial positioning, but also builds a solid defense for patient safety through real-time dynamic monitoring, and accumulates valuable objective and quantitative quality-control data for medical institutions.<\/p><p data-path-to-node=\"32\">With the continuous evolution of medical technology and its synergistic innovation with adaptive radiotherapy (ART), artificial intelligence (AI) and other cutting-edge fields, vision localization system based on binocular scatter 3D camera will surely become an indispensable core pillar in the system of precision radiotherapy, contributing a key force in enhancing the effectiveness of cancer treatment and improving the quality of patient's survival.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45ed7c8 elementor-widget elementor-widget-button\" data-id=\"45ed7c8\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/aiportek.com\/hk\/ensenso-3d-camera-series\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Go to the Ensenso 3D product page<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t<div class=\"elementor-element elementor-element-9049411 e-flex e-con-boxed e-con e-parent\" data-id=\"9049411\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cfcf4de e-flex e-con-boxed e-con e-parent\" data-id=\"cfcf4de\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dbc1b58 elementor-widget elementor-widget-heading\" data-id=\"dbc1b58\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-xl\">Other Articles<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74adc8f elementor-posts--align-left elementor-grid-3 elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-posts--thumbnail-top elementor-card-shadow-yes elementor-posts__hover-gradient elementor-widget elementor-widget-posts\" data-id=\"74adc8f\" data-element_type=\"widget\" data-settings=\"{&quot;cards_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:100,&quot;sizes&quot;:[]},&quot;cards_columns&quot;:&quot;3&quot;,&quot;cards_columns_tablet&quot;:&quot;2&quot;,&quot;cards_columns_mobile&quot;:&quot;1&quot;,&quot;cards_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;cards_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"posts.cards\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-cards elementor-grid\" role=\"list\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-34811 post type-post status-publish format-standard has-post-thumbnail hentry category-18 tag-ids tag-57\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/aiportek.com\/en\/3d-camera-radiotherapy-patient-positioning-hongke\/\" tabindex=\"-1\" target=\"_blank\"><div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"607\" src=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6.webp\" class=\"attachment-full size-full wp-image-34815\" alt=\"\" srcset=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6.webp 1080w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-300x169.webp 300w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-1024x576.webp 1024w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-768x432.webp 768w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-18x10.webp 18w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-6-600x337.webp 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/div><\/a>\n\t\t\t\t<div class=\"elementor-post__badge\">Hongke Case<\/div>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/aiportek.com\/en\/3d-camera-radiotherapy-patient-positioning-hongke\/\" target=\"&quot;_blank&quot;\">\n\t\t\t\tHONGKE Solution] 3D Camera Radiotherapy Positioning System - Sub-millimeter Surface Image Positioning\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>HongKe offers radiotherapy vision positioning solutions based on high precision binocular scatter 3D cameras. With sub-millimeter accuracy (&lt;0.1mm) and anti-interference ability, no marking real-time dynamic tracking, the perfect solution for nasopharyngeal cancer and other precise radiotherapy positioning and breathing micro-movement pain points. Please contact our Hong Kong and Southeast Asia team for free SDK and technical support.\n<\/p>\n\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/aiportek.com\/en\/3d-camera-radiotherapy-patient-positioning-hongke\/\" aria-label=\"Read more about 3D Camera Radiotherapy Positioning System - Sub-millimeter Surface Image Positioning\" tabindex=\"-1\" target=\"_blank\">\n\t\t\tRead more\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-author\">\n\t\t\tHongKeTechnology\t\t<\/span>\n\t\t\t\t<span class=\"elementor-post-date\">\n\t\t\tMay 19, 2026\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-34796 post type-post status-publish format-standard has-post-thumbnail hentry category-18 tag-aimotive tag-64\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/aiportek.com\/en\/aisim-asil-d-compliance-sea-ev-simulation-hongke\/\" tabindex=\"-1\" target=\"_blank\"><div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"1456\" height=\"816\" src=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/04\/\u81ea\u52a8\u9a7e\u9a76\u6570\u636e\u95ed\u73af.webp\" class=\"attachment-full size-full wp-image-34417\" alt=\"\" srcset=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/04\/\u81ea\u52a8\u9a7e\u9a76\u6570\u636e\u95ed\u73af.webp 1456w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/04\/\u81ea\u52a8\u9a7e\u9a76\u6570\u636e\u95ed\u73af-300x168.webp 300w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/04\/\u81ea\u52a8\u9a7e\u9a76\u6570\u636e\u95ed\u73af-1024x574.webp 1024w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/04\/\u81ea\u52a8\u9a7e\u9a76\u6570\u636e\u95ed\u73af-768x430.webp 768w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/04\/\u81ea\u52a8\u9a7e\u9a76\u6570\u636e\u95ed\u73af-18x10.webp 18w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/04\/\u81ea\u52a8\u9a7e\u9a76\u6570\u636e\u95ed\u73af-600x336.webp 600w\" sizes=\"(max-width: 1456px) 100vw, 1456px\" \/><\/div><\/a>\n\t\t\t\t<div class=\"elementor-post__badge\">Hongke Case<\/div>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/aiportek.com\/en\/aisim-asil-d-compliance-sea-ev-simulation-hongke\/\" target=\"&quot;_blank&quot;\">\n\t\t\t\tHongke Solution] aiSim Helps Southeast Asian EVs to Comply with Overseas Standards: ASIL-D Certification Simulation Solution\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>aiSim is the world's first automated driving simulation platform certified by ISO 26262 ASIL-D. aiSim is the first automated driving simulation platform certified by ISO 26262 ASIL-D in the world. Focusing on the compliance pain points of Southeast Asian EV companies going to Europe and the U.S., aiSim provides legally binding test reports to help you shorten the validation cycle, significantly reduce compliance costs and accelerate product launches.<\/p>\n\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/aiportek.com\/en\/aisim-asil-d-compliance-sea-ev-simulation-hongke\/\" aria-label=\"Read more about [Hongke Solution] aiSim Helps Southeast Asian EVs Comply with Overseas Standards: ASIL-D Certification Simulation Solution\" tabindex=\"-1\" target=\"_blank\">\n\t\t\tRead more\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-author\">\n\t\t\tHongKeTechnology\t\t<\/span>\n\t\t\t\t<span class=\"elementor-post-date\">\n\t\t\tMay 15, 2026\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-34673 post type-post status-publish format-standard has-post-thumbnail hentry category-18 tag-msr tag-52\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/aiportek.com\/en\/transportation-data-logger-selection-guide-hongke\/\" tabindex=\"-1\" target=\"_blank\"><div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"702\" src=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1.webp\" class=\"attachment-full size-full wp-image-34674\" alt=\"\" srcset=\"https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1.webp 1080w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-300x195.webp 300w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-1024x666.webp 1024w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-768x499.webp 768w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-18x12.webp 18w, https:\/\/aiportek.com\/wp-content\/uploads\/2026\/05\/640-1-600x390.webp 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/div><\/a>\n\t\t\t\t<div class=\"elementor-post__badge\">Hongke Case<\/div>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/aiportek.com\/en\/transportation-data-logger-selection-guide-hongke\/\" target=\"&quot;_blank&quot;\">\n\t\t\t\tHongke Case] Transportation Logger Buyer's Guide: Precision Equipment and Cold Chain Logistics Monitoring Solutions\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>Difficulty in clarifying the responsibility of cargo transportation damage? HongKe provides professional transportation recorder selection guide. In-depth analysis of impact monitoring, temperature and humidity tracking, real-time alarms and range options help precision instruments, electrical equipment and high-value cargoes to travel safely to the sea. Check out our nanny-grade logistics monitoring solutions now!<\/p>\n\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/aiportek.com\/en\/transportation-data-logger-selection-guide-hongke\/\" aria-label=\"Read more about Hongke Case] Transportation Logger Buyer&#039;s Guide: Precision Equipment and Cold Chain Logistics Monitoring Solutions\" tabindex=\"-1\" target=\"_blank\">\n\t\t\tRead more\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-author\">\n\t\t\tHongKeTechnology\t\t<\/span>\n\t\t\t\t<span class=\"elementor-post-date\">\n\t\t\tMay 12, 2026\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t<div class=\"e-load-more-anchor\" data-page=\"1\" data-max-page=\"31\" data-next-page=\"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/posts\/34811\/page\/2\/\"><\/div>\n\t\t\t\t<nav class=\"elementor-pagination\" aria-label=\"Pagination\">\n\t\t\t<span class=\"page-numbers prev\">\"<\/span>\n<span aria-current=\"page\" class=\"page-numbers current\"><span class=\"elementor-screen-only\">Page<\/span>1<\/span>\n<a class=\"page-numbers\" href=\"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/posts\/34811\/page\/2\/\"><span class=\"elementor-screen-only\">Page<\/span>2<\/a>\n<a class=\"page-numbers\" href=\"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/posts\/34811\/page\/3\/\"><span class=\"elementor-screen-only\">Page<\/span>3<\/a>\n<span class=\"page-numbers dots\">...<\/span>\n<a class=\"page-numbers\" href=\"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/posts\/34811\/page\/5\/\"><span class=\"elementor-screen-only\">Page<\/span>5<\/a>\n<a class=\"page-numbers next\" href=\"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/posts\/34811\/page\/2\/\">\"<\/a>\t\t<\/nav>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>HongKe offers radiotherapy vision positioning solutions based on high precision binocular scatter 3D cameras. With sub-millimeter accuracy (&lt;0.1mm) and anti-interference ability, no marking real-time dynamic tracking, the perfect solution for nasopharyngeal cancer and other precise radiotherapy positioning and breathing micro-movement pain points. Please contact our Hong Kong and Southeast Asia team for free SDK and technical support.\n<\/p>","protected":false},"author":1,"featured_media":34815,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[18],"tags":[70,57],"class_list":["post-34811","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-18","tag-ids","tag-57"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/posts\/34811","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/comments?post=34811"}],"version-history":[{"count":4,"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/posts\/34811\/revisions"}],"predecessor-version":[{"id":34819,"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/posts\/34811\/revisions\/34819"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/media\/34815"}],"wp:attachment":[{"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/media?parent=34811"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/categories?post=34811"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/aiportek.com\/en\/wp-json\/wp\/v2\/tags?post=34811"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}