Search

TrackSense Pro Basic - Conductivity and Temperature Sensors

TrackSense Pro Basic Wireless Data Logger

Conductivity and Temperature Sensors

The conductivity and temperature sensors have a conductivity range of 0 to 200 µS/cm and a temperature range of 0 to +100 °C. The conductivity measurements are suitable for control/monitoring of industrial processes and for validation of the washing and disinfecting process in hospitals regulated by EN ISO 15883:2009. The data logger can be used in the pharmaceutical, medical/hospital, fermentation, food and beverage, sugar, petroleum, chemical and power plant industries.

 

The high-quality wireless TrackSense Pro Basic data logger is made of high-strength stainless steel and offers high-end technology for stable and highly accurate measurements in different thermal processes.

 

The TrackSense Pro DataCORDER series is equipped with an interchangeable sensor option that unlocks multiple measurement parameters:

 

✓ Temperature

✓ Pressure

✓ Conductivity

✓ Relative Humidity

✓ Vacuum

✓ Vapor penetration

 

The DataCORDER can be easily activated and read by multiple readout stations and combined with the Sky Module via wireless communication to obtain real-time data.

Sensors with this logger configuration:Conductivity and Temperature SensorsRecorders with this sensor configuration:LAN 3G
Conductivity range:0 to 200 μS/cmWorking temperature:+5 to +50°C
Measurement Principle:Conductivity/ResistanceSurface material:316 Liter Stainless Steel
Sensor element:Conductivity / Pt1000Diameter of the logger:25mm
Connection material:Peek (FDA compliant)Recorder length:44mm
Dimensions L x D:37 mm x 25 mm / 13 mmWith battery weight:48g
Immersion depth:0.1 μS/cmMemory capacity:120,000 data points/60,000 sample values
Conductivity accuracy:± 1 μS/cm or ± 2.5 % of reading, whichever is worse.Minimum sampling rate:1s
IP Class:IP67Maximum sampling rate:24h
Temperature range:0 to +100°C*Maximum startup delay:14 days
Temperature accuracy:± 0.05 °CBenan:Ex II1GD Ex ia IIC T3 Ga, -50 °C ≤ Tamb ≤ +105 °C
*Conductivity sensors are not for vapors.
Designed for sterilization, but can be autoclaved at +121 °C.
Time accuracy:±5s/24h
  Battery:TSP Standard Battery
  Please note: If the equipment is to be used in an ATEX environment, the special conditions for safe use specified in section 17 of the ATEX Certificate must be taken into account.

Sensor Options

Key Benefits and Features

  • One Logger - Multiple Sensor Options
  • Conforms to 21 CFR Part 11
  • Real-time data of SKY module
  • User-friendly verification software
  • Works with E-Val Pro thermocouple system

Software

ValSuite software is the industry's leading verification and calibration software and is highly credited with countless reporting options, impeccable data integrity, user calibration options and data analysis capabilities.

 

The software is used to run all of ELLAB's hardware and can combine various measurement systems into a unified study. In addition to its wide range of features, ValSuite complies with FDA 21 CFR Part 11 and is designed according to the GAMP guidelines. In addition, the software automatically generates PDF reports with clear pass/fail indications and can be run on stand-alone PCs or networked computers.

✓ Complies with FDA 21 CFR Part 11
✓ safe and reliable
✓  Windows Security Options
✓ Compatible with Windows 10
✓ Available in multiple languages
✓ Suitable for various applications
✓ Multiple Reporting Options

  • One software platform for all Ellab devices
  • Combine TrackSense data logger and E-Val Pro wired thermocouple system in the same session
  • Automatic PDF report generation with clear pass/fail indication
  • Runs on standalone PC or network

Applications

Sterilizer

Sterilizers are used in medical and pharmaceutical applications to prepare items for future autoclaving (e.g. surgical instruments for removing residues such as blood and proteins) or sterilizing (semi-sterilizing) items for later use.

Related Products

Contact Hongke to help you solve your problems.

Let's have a chat