- Home
- Technical Products
Enterprise Cloud IT Solutions
Test Measurement
- Solutions
Enterprise Cloud IT Solutions
Test Measurement
- Resource Center
- About Us
EN
TrackSense Pro Basic-4Bar壓力傳感器

TrackSense Pro Basic Wireless Data Logger
4Bar壓力傳感器
4 Bar 壓力傳感器的壓力範圍為 10mBar 至 4 Bar Absolute,測量精度為 ± 0.25% 滿量程。它可用於食品、制藥和醫療行業,適用於蒸煮滅菌、蒸汽滅菌、烤箱、環境室等應用。
高質量無線 TrackSense Pro Basic數據記錄儀由高強度不銹鋼制成,並提供高端技術,可在不同的熱過程中進行穩定和高精度的測量。
The TrackSense Pro DataCORDER series is equipped with an interchangeable sensor option that unlocks multiple measurement parameters:
✓ Temperature
✓ Pressure
✓ Conductivity
✓ Relative Humidity
✓ Vacuum
✓ Vapor penetration
The DataCORDER can be easily activated and read by multiple readout stations and combined with the Sky Module via wireless communication to obtain real-time data.
- Technical Parameters
Sensors with this logger configuration: | 4BAR壓力傳感器 | Recorders with this sensor configuration: | 還有3G |
---|---|---|---|
Pressure measurement range: | 10 mBar 至4 Bar ABS(0 至+140 °C 校準) | Operational pressure: | 0.001 mBar to 10 Bar ABS |
Measurement Principle: | Piezoresistive | Working temperature: | -20 to +150°C |
Sensor element: | Strain gauge | Surface material: | 316 Liter Stainless Steel |
Measurement accuracy: | ± 0.25% Full Scale | Diameter of the logger: | 25毫米 |
Recorder length: | 44毫米 | ||
With battery weight: | 48克 | ||
Memory capacity: | 120,000 個數據點/60,000 個樣本值 | ||
Minimum sampling rate: | 0.33秒 | ||
Maximum sampling rate: | 24 hours | ||
Maximum startup delay: | 14 days | ||
Benan: | Ex II1GD Ex ia IIC T3 Ga, -50 °C ≤ Tamb ≤ +105 °C | ||
Time accuracy: | ±5秒/24小時 | ||
Battery: | TSP Standard Battery | ||
Please note: If the equipment is to be used in an ATEX environment, the special conditions for safe use specified in section 17 of the ATEX Certificate must be taken into account. |
Sensor Options
Internal Temperature Sensor
Rigid Temperature Sensor
Double Rigid Temperature Sensor
Rigid and SmartFlex Temperature Sensor
Rigid Multipoint Temperature Sensor
Semi Flexible Temperature Sensor
Double Semi Flexible Temperature Sensor
Rugged Flexible Temperature Sensor
SmartFlex Temperature Sensor
Double SmartFlex Temperature Sensor
Temperature Thermocouple Sensor
4 Bar Pressure Sensor
6 Bar Pressure Sensor
8 Bar Pressure Sensor
Pressure and Rigid Temperature Sensor
Vacuum Sensor
Relative Humidity and Temperature Sensor
Conductivity and Temperature Sensor
High Range Conductivity and Temperature Sensor
Automarker
Previous
Next
Key Benefits and Features
- One Logger - Multiple Sensor Options
- Conforms to 21 CFR Part 11
- Real-time data of SKY module
- User-friendly verification software
- Works with E-Val Pro thermocouple system

Software
ValSuite software is the industry's leading verification and calibration software and is highly credited with countless reporting options, impeccable data integrity, user calibration options and data analysis capabilities.
The software is used to run all of ELLAB's hardware and can combine various measurement systems into a unified study. In addition to its wide range of features, ValSuite complies with FDA 21 CFR Part 11 and is designed according to the GAMP guidelines. In addition, the software automatically generates PDF reports with clear pass/fail indications and can be run on stand-alone PCs or networked computers.
✓ Complies with FDA 21 CFR Part 11
✓ safe and reliable
✓ Windows Security Options
✓ Compatible with Windows 10
✓ Available in multiple languages
✓ Suitable for various applications
✓ Multiple Reporting Options
- One software platform for all Ellab devices
- Combine TrackSense data logger and E-Val Pro wired thermocouple system in the same session
- Automatic PDF report generation with clear pass/fail indication
- Runs on standalone PC or network
Applications

Ethylene oxide sterilization
Ethylene oxide sterilization is a low temperature process used in the pharmaceutical and medical industries to reduce the level of infectious agents.This process is preferred for products that cannot withstand the high temperatures typical of autoclaves.Key parameters include temperature, humidity and pressure levels.

Environmental Test Room
Environmental test chambers are suitable for a variety of applications: product shelf-life, stability and packaging testing, light and temperature assessment studies, electronic component aging, plant growth, and more.
They are characterized by precise control of parameters such as temperature and relative humidity.

Hydrogen Peroxide
Hydrogen peroxide sterilization is a low-pressure, low-temperature, non-toxic process used in the pharmaceutical and medical industries to reduce the level of infectious agents. This process is preferred for products that cannot withstand the heat of a typical high-pressure sterilizer or have space for diffusion limitations, such as low-lumen medical equipment.
Key parameters include pressure/vacuum, transmitted RF energy, H2O2 concentration and temperature. Humidity can also be measured.

Sterilizer
Sterilizers are used in medical and pharmaceutical applications to prepare items for future autoclaving (e.g. surgical instruments for removing residues such as blood and proteins) or sterilizing (semi-sterilizing) items for later use.