TrackSense Pro Basic - Relative Humidity and Temperature Sensor

TrackSense Pro Basic Wireless Data Logger

Relative Humidity and Temperature Sensors

The relative humidity and temperature sensors have a temperature range of 0 to +90 °C with an accuracy of ± 0.1 °C (10 to +90 °C range). The sensor has a relative humidity range of 0 to 100% RH with an accuracy of ± 2% RH (calibration range 10 to 90%). It can be used for applications in the pharmaceutical industry and is particularly suitable for determining humidity levels during validation of warehouses, stabilization chambers and EtO sterilization processes.

 

The high quality wireless TrackSense Pro Basic datalogger is made of high-strength stainless steel and offers high-end technology for stable and highly accurate measurements in different thermal processes.

 

The TrackSense Pro DataCORDER series is equipped with an interchangeable sensor option that unlocks multiple measurement parameters:

 

✓ Temperature

✓ Pressure

✓ Conductivity

✓ Relative Humidity

✓ Vacuum

✓ Vapor penetration

 

The DataCORDER can be easily activated and read by multiple readout stations and combined with the Sky Module via wireless communication to obtain real-time data.

Sensors with this logger configuration:Relative Humidity and Temperature SensorsRecorders with this sensor configuration:PRO BASIC 3G
RH measurement range (0 to +90 °C):0 - 100% (calibration 10-90%)Working temperature:0 to +90°C
Measurement Principle:Capacitive inductive/resistiveOperational pressure:0.001 mBar to 10 Bar ABS
Sensor element:Capacitance/Pt1000Surface material:316 Liter Stainless Steel
RH accuracy at 25 °C without condensation (10% to 90%):± 2%Diameter of the logger:25mm
RH Resolution:0.10%Recorder length:44mm
RH Response Time (63% in slow moving air):<15 sWith battery weight:48g
Temperature measurement range:0 to +90 °C (calibrated 10-90 °C)Memory capacity:120,000 data points/60,000 sample values
Temperature accuracy: Minimum sampling rate:1s
+10 to +90°C:± 0.1 °CMaximum sampling rate:24h
Temperature resolution:0.01°CMaximum startup delay:14 days
Temperature response time: Benan:Ex II1GD Ex ia IIC T3 Ga, -30 °C ≤ Tamb ≤ +105 °C
T-63%:6.5 sTime accuracy:±5s/24h
T-90%:17 sBattery:TSP Standard Battery
*Requires ValSuite 5.2 or later.Please note: If the equipment is to be used in an ATEX environment, the special conditions for safe use specified in section 17 of the ATEX Certificate must be taken into account.

Sensor Options

Key Benefits and Features

  • One Logger - Multiple Sensor Options
  • Conforms to 21 CFR Part 11
  • Real-time data of SKY module
  • User-friendly verification software
  • Works with E-Val Pro thermocouple system

Software

ValSuite software is the industry's leading verification and calibration software and is highly credited with countless reporting options, impeccable data integrity, user calibration options and data analysis capabilities.

 

The software is used to run all of ELLAB's hardware and can combine various measurement systems into a unified study. In addition to its wide range of features, ValSuite complies with FDA 21 CFR Part 11 and is designed according to the GAMP guidelines. In addition, the software automatically generates PDF reports with clear pass/fail indications and can be run on stand-alone PCs or networked computers.

✓ Complies with FDA 21 CFR Part 11
✓ safe and reliable
✓  Windows Security Options
✓ Compatible with Windows 10
✓ Available in multiple languages
✓ Suitable for various applications
✓ Multiple Reporting Options

  • One software platform for all Ellab devices
  • Combine TrackSense data logger and E-Val Pro wired thermocouple system in the same session
  • Automatic PDF report generation with clear pass/fail indication
  • Runs on standalone PC or network

Applications

Warehouse

Warehouse environments in the pharmaceutical, medical and food industries may require regulatory compliance, validation and monitoring.

Temperature and humidity are the most common critical parameters that cannot exceed certain limits and need to be recorded accurately.

Environmental Test Room

Environmental test chambers are suitable for a variety of applications: product shelf-life, stability and packaging testing, light and temperature assessment studies, electronic component aging, plant growth, and more. 

They are characterized by precise control of parameters such as temperature and relative humidity. 

Hydrogen Peroxide

Hydrogen peroxide sterilization is a low-pressure, low-temperature, non-toxic process used in the pharmaceutical and medical industries to reduce the level of infectious agents. This process is preferred for products that cannot withstand the heat of a typical high-pressure sterilizer or have space for diffusion limitations, such as low-lumen medical equipment.

Key parameters include pressure/vacuum, transmitted RF energy, H2O2 concentration and temperature. Humidity can also be measured.

Ethylene oxide sterilization

Ethylene oxide sterilization is a low temperature process used in the pharmaceutical and medical industries to reduce the level of infectious agents.This process is preferred for products that cannot withstand the high temperatures typical of autoclaves.Key parameters include temperature, humidity and pressure levels. 

Related Products

Contact Hongke to help you solve your problems.

Let's have a chat