- Home
- Technical Products
Enterprise Cloud IT Solutions
Test Measurement
- Solutions
Enterprise Cloud IT Solutions
Test Measurement
Industrial Internet of Things
- Resource Center
- About Us
- EN
TrackSense Pro Basic L-二氧化碳傳感器 0-10%
TrackSense Pro Basic L Wireless Data Logger
二氧化碳傳感器 0-10%
帶有 CO2 傳感器的 TrackSense Pro 數據記錄儀可提供孵化過程中 CO2 濃度的準確讀數。CO2 傳感器的測量範圍為 0-10%,可提供無線測量,用於驗證或監測制藥和醫療行業內的生物細胞生長培養箱。CO2 傳感器采用非色散紅外 (NDIR) 技術設計,可提供 +/- 2% FS (0.2%) 的高精度測量,從而確保細胞的最佳生長環境。
CO2 傳感器 0-10% 是高濕度 CO2 培養箱的理想選擇,因為該傳感器可以在高達 0-95% 的非冷凝濕度環境中運行。
高質量無線 TrackSense Pro Basic L 數據記錄儀由高強度不銹鋼制成,並提供高端技術,可在不同的熱過程中進行穩定和高精度的測量。
The TrackSense Pro DataCORDER series is equipped with an interchangeable sensor option that unlocks multiple measurement parameters:
✓ Temperature
✓ Pressure
✓ Conductivity
✓ Relative Humidity
✓ Vacuum
✓ Vapor penetration
The DataCORDER can be easily activated and read by multiple readout stations and combined with the Sky Module via wireless communication to obtain real-time data.
- Technical Parameters
Sensors with this logger configuration: | 二氧化碳傳感器0-10% | Recorders with this sensor configuration: | PRO BASIC L 3G |
---|---|---|---|
Measurement range: | 0-10% | Working temperature: | 0 至+50°C |
Measurement Principle: | NDIR(非色散紅外線感測器) | Operational pressure: | 0.001 mBar 至10 Bar ABS |
Sensor element: | 紅外線 | Surface material: | 316 Liter Stainless Steel |
校準測量範圍: | 0-10% | Diameter of the logger: | 25mm |
Precision: | ± 0.2% | Recorder length: | 68.8mm |
工作溫度範圍: | 0 至+50°C | With battery weight: | 80g |
工作相對濕度範圍: | 0 到95% 非冷凝 | Memory capacity: | 120,000 data points / 120,000 sample values |
工作壓力範圍: | 800 至1,200 mBar(內建壓力補償) | Minimum sampling rate: | 1s |
Minimum sampling rate: | 2分鐘 | Maximum sampling rate: | 24h |
Maximum startup delay: | 14 days | ||
Benan: | Not ATEX certified | ||
Time accuracy: | ±5s/24h | ||
Battery: | TSP Standard Battery | ||
*需要ValSuite® 5.2.0.9 或更高版本 |
Sensor Options
Internal Temperature Sensor
Rigid Temperature Sensor
Double Rigid Temperature Sensor
Rigid and SmartFlex Temperature Sensor
Rigid Multipoint Temperature Sensor
Semi Flexible Temperature Sensor
Double Semi Flexible Temperature Sensor
Rugged Flexible Temperature Sensor
SmartFlex Temperature Sensor
Double SmartFlex Temperature Sensor
Temperature Thermocouple Sensor
4 Bar Pressure Sensor
6 Bar Pressure Sensor
8 Bar Pressure Sensor
Pressure and Rigid Temperature Sensor
Vacuum Sensor
Relative Humidity and Temperature Sensor
Conductivity and Temperature Sensor
High Range Conductivity and Temperature Sensor
Automarker
Previous
Next
Key Benefits and Features
- One Logger - Multiple Sensor Options
- Conforms to 21 CFR Part 11
- Real-time data of SKY module
- User-friendly verification software
- Works with E-Val Pro thermocouple system
Software
ValSuite software is the industry's leading verification and calibration software and is highly credited with countless reporting options, impeccable data integrity, user calibration options and data analysis capabilities.
The software is used to run all of ELLAB's hardware and can combine various measurement systems into a unified study. In addition to its wide range of features, ValSuite complies with FDA 21 CFR Part 11 and is designed according to the GAMP guidelines. In addition, the software automatically generates PDF reports with clear pass/fail indications and can be run on stand-alone PCs or networked computers.
✓ Complies with FDA 21 CFR Part 11
✓ safe and reliable
✓ Windows Security Options
✓ Compatible with Windows 10
✓ Available in multiple languages
✓ Suitable for various applications
✓ Multiple Reporting Options
- One software platform for all Ellab devices
- Combine TrackSense data logger and E-Val Pro wired thermocouple system in the same session
- Automatic PDF report generation with clear pass/fail indication
- Runs on standalone PC or network
Applications
培養箱
In microbiology, an incubator is a device used to control the temperature, humidity, and other conditions under which microbial cultures grow.
More advanced incubators may have the ability to reduce temperature (through cooling) and/or control humidity or CO2 levels. This feature is designed for cell growth.