- Home
- Technical Products
High-Performance Data and Automation
ADAS Simulation and Testing Framework
In-Vehicle Network Communications
Industrial Internet of Things and Digital Factories
AI Machine Vision
Pharmaceutical Cold Chain and Environmental Monitoring
Laboratory Automation and Microfluidics
Environmental Monitoring and Facility Management
Critical Infrastructure Communications and Remote Collaboration
Professional Electronic Testing and Measurement
- Solutions
High-Performance Data and Automation
ADAS Simulation and Testing Framework
In-Vehicle Network Communications
Industrial Internet of Things and Digital Factories
AI Machine Vision
Pharmaceutical Cold Chain and Environmental Monitoring
Laboratory Automation and Microfluidics
Environmental Monitoring and Facility Management
Critical Infrastructure Communications and Remote Collaboration
- Latest Case Studies
- About Us
EN
Fiber Optic Spectrometer SP303HRS
High Resolution Low Noise Acoustic Spectrometer
- High Resolution Optical Desk
- Scientific High Performance
- Very low dark noise and stray light
- Wide dynamic range and high signal-to-noise ratio
- High UV quantum efficiency
- Flexible optical input directly to the slit or via fiber optics
- Designed from the ground up for a wide range of applications
- High-speed data acquisition
- Standard design allows for a spectral range of 200-1050nm.
effectivity
SP303HRS using Hamamatsu S7031-1006 (UV-enhanced coating) detector.
Ideal for UV/Visible/NIR spectrometers.
high signal-to-noise ratio
The array driver electronics are designed for highly sensitive and stable operation.
The signal to noise ratio is 1000:1.
- parameters
/ Sensor
| Hamamatsu S7031-1006S backthined CCD ▶Number of pixels: 1024 x 58 ▶ Sensing pixel size: 24μm X 24μm ▶ Pixel depth: 300V Ke- (vertical) 660 Ke- (horizontal) ▶ Efficiency: >90% @650nm, 65% @250nm ▶ Sensitivity: ~0.065counts/e- ▶Cooling: Level 1 TE Cooling |
Dark noise RMS: < 2 RMS counts @ 35 msec
Signal to noise ratio: 1000 : 1
Fiber Optic Coupler: SMA905 of Standard FC
/Wavelength Range
Full range: 200 ~ 1050 nm
UV range: 200 ~ 450 nm
Visible light range: 380 ~ 760 nm
NIR range: 550 ~ 1050 nm
Filter ordering: Installation of long pass filters or linear variable filters depending on the wavelength coverage.
Optical resolution: 0.2 ~ 7 nm FWHM
Spurious light level: < 0.01% @532 nm (< 0.05% AVG)
Computer Interface: USB 1.1/2.0 compatible
Minimum exposure time: 7 msec
Trigger Mode: Free Run S/W Trigger H/W Trigger
Operating System: Windows 7/10 (32 64 bit)
SDK Support: Visual C++ / Visual Basic / LabVIEW