- Home
- Technical Products
High-Performance Data and Automation
ADAS Simulation and Testing Framework
In-Vehicle Network Communications
Industrial Internet of Things and Digital Factories
AI Machine Vision
Pharmaceutical Cold Chain and Environmental Monitoring
Laboratory Automation and Microfluidics
Environmental Monitoring and Facility Management
Critical Infrastructure Communications and Remote Collaboration
Professional Electronic Testing and Measurement
- Solutions
High-Performance Data and Automation
ADAS Simulation and Testing Framework
In-Vehicle Network Communications
Industrial Internet of Things and Digital Factories
AI Machine Vision
Pharmaceutical Cold Chain and Environmental Monitoring
Laboratory Automation and Microfluidics
Environmental Monitoring and Facility Management
Critical Infrastructure Communications and Remote Collaboration
- Latest Case Studies
- About Us
EN
Fiber Optic Spectrometer SP642
Low Noise Non-TE Cooled Spectrometer
- Scientific performance at low cost
- Low dark noise and stray light
- Good dynamic range and high signal-to-noise ratio
- High UV quantum efficiency
- Flexible optical input directly to the slit or via fiber optics
- Wide range of applications
- High-speed data acquisition
- Standard design allows for a range of 200-1050 nm.
- Automatic shutter in dark conditions
effectivity
SP642 using Hamamatsu S10420-1106 (non-TE cooled FFT CCD detector.
(Ideal for UV/Visible/NIR spectroscopy).
high signal-to-noise ratio
The array driver electronics are designed for highly sensitive and stable operation.
The signal-to-noise ratio is 450:1.
- parameters
/ Sensor
Hamamatsu S10420-1106(TE-free Cooling Backthinned FFT CCD)Number of pixels: 2048 X 64
Sensing pixel size: 14 μm X 14 μm
Pixel depth: 200 Ke-
Quantum efficiency: >90% @650 nm, 65% @250 nm
Dark noise RMS: < 7 RMS counts @ 35 msec
Signal-to-noise ratio: 450 : 1
Fiber Optic Coupler: SMA905 of Standard FC
/Wavelength Range
Full range: 200 ~ 1050 nm
UV range: 200 ~ 450 nm
Visible light range: 380 ~ 760 nm
NIR range: 550 ~ 1050 nm
Filter ordering: Installation of long pass filters or linear variable filters depending on the wavelength coverage.
Optical resolution: 0.2 ~ 7 nm FWHM
Spurious light level: < 0.01% @632 nm (< 0.5% AVG)
Computer Interface: USB 1.1/2.0 compatible
Minimum exposure time: 7 msec
Trigger Mode: Free Run S/W Trigger H/W Trigger
Operating System: Window® XP / VISTA / Win7(32 / 64bit) / Win8.1 (32 / 64bit)