Search

Multi-function data logger - 2 MiniDIN inputs and 2 universal inputs for temperature, humidity, CO2, barometer

M1323

Battery-powered data logger with built-in CO2 and atmospheric pressure sensors and four general purpose inputs for measuring temperature, humidity, 0-10V voltage, 0-20mA current, bi-state signals, and pulse counting.

The multifunction data logger can be permanently installed on an Ethernet network or used as a portable device.

A traceable calibration certificate to EN ISO/IEC17025 is included.

 

The Multi-Function Data Logger is a battery-powered data logger capable of measuring and recording sensor and electrical values through its inputs.

 

The multifunctional data logger can be connected to an Ethernet network. Measurements can be viewed on a browser, saved and downloaded for subsequent analysis.

Warranty: 3 years

Measurement parameters
Temperature
Relative Humidity
Count (Dew Point...)
carbon dioxide CO2
Atmospheric Pressure
Current
Voltage
Dual State Signal
Pulse


Temperature Sensor - External Probe PT1000
Measurement range: -200 to +600 °C
Measurement accuracy: ±0.2°C (-200 to +100°C); ±0.2% of measured value in the +100 to +600°C range
Resolution: 0.1 °C


Temperature + Humidity Sensor - External Probe T+RH DIGI
Measurement range: depends on the connected probe Digi/M
Measurement accuracy: depends on the connected probe Digi/M
Resolution: 0.1 °C


outdoor spot
Measurement range: depends on the connected probe Digi/M
Measurement accuracy: depends on the connected probe Digi/M
Resolution: 0.1 °C


Atmospheric Pressure Sensor
Measurement range: 700 hPa to 1100 hPa
Measurement accuracy: ±1.3 hPa at 23 °C
Resolution: 0.1 hPa


Carbon Dioxide Sensor
Measurement range: 0 to 2 000 ppm
Measurement accuracy: 50 ppm + 2% of the measured value at 23 °C and 1013 hPa
Resolution: 1 ppm
DC Voltage:
Measurement range: 0 to 10 V
Measurement accuracy: ±10 mV
Resolution: better than 100 µV


DC Current
Measurement range: 0 to 20 mA
Measurement accuracy: ±20 µA
Resolution: better than 0.1 µA


Binary Signal
Input voltage when level is "on": 2 V
Min/Max input voltage: 0 V/+30 V DC
Impedance when "on": 300 kOhm


Counter Input
Counter range: 24-bit (16,777,215), counter overflow allowed
Maximum input frequency: 200 Hz


General Technical Data
Operating temperature: -10 to +60 °C
Channels: Built-in CO2 atmospheric pressure sensor, 2 external temperature probes or connectable temperature + humidity probes, 2 binary, counter, voltage and current inputs
Measurement: Dew point temperature, Absolute humidity, Specific humidity, Mixing ratio, Specific enthalpy
Total storage capacity: 1,000,000 values in non-cyclic recording mode; 600,000 values in cyclic recording mode
Recording interval: adjustable from 1 second to 24 hours
Display and alarm updates: every 10 seconds
Data logging modes: Non-cyclic - stops logging when the memory is full; cyclic - the earliest data is overwritten with new data after the memory is full
Available Temperature Units: Celsius, Fahrenheit
Communication Interface: Ethernet, USB, RS232
Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK.
Alarm Protocol: Email
Power: AC adapter 230Vac/5Vdc (required for Ethernet interface)
Battery life: 3 - 4 weeks
Protection level: IP20
Dimensions (without connector): 178 x 95 x 37 mm without connection cable
Weight (including battery): approx. 380 g
Warranty: 3 years

  • M1323
  • Operator's Manual
  • Traceable calibration certificate
  • 3 AA type rechargeable batteries
  • Power supply
  • USB Cable
  • Wall Mount Bracket
  • Free analysis software COMET Vision

Delivery without external probe