Search

GRD1R LH Temperature Gradient Incubator

Easily realize multi-sample and multi-hole temperature difference test.

Applications

Seed Dormancy

Seeds germinate at constant or variable temperatures.

Germination Rate Measurement

Other applications (seed protection, biofuels, food crop research)

GRD1R LH Temperature Gradient Incubator

The GRD1R LH Temperature Gradient Culture Plate is designed to provide easy access to feedback results of seeds, small plants and animals, microorganisms, and various small components or materials at different temperatures. The design principle is to heat one side of the aluminum plate while cooling the other side, thus creating a temperature gradient on the plate surface, and rotating the plate through the gradient again by 90 degrees to create a porous temperature difference result.

 

The gradient system is capable of multi-directional temperature cycling. The system can trace the temperature gradient in a defined direction within 24 hours, after which the system automatically rotates the direction of the gradient by 90 degrees in the layout, and then cycling back to the original position in order to produce orthogonal data between the highest and lowest temperatures.

Advantageous highlights of temperature gradient culture plates

Real-time temperature control

The temperature gradient can be set to flip the gradient 90 degrees at any time to create a temperature difference test. 24-hour adjustable timer allows 2-stage control/switching of the gradient direction over a 24-hour cycle.

Multi-sample testing

Plexiglass panels can be moved for warming, and are divided into 196 incubation zones, each with a different temperature, allowing a wide range of products to be tested.

Safeguarding Security Experiments

Over-temperature protection, each edge is protected by a fixed temperature disconnect.
Durable and rugged all-in-one system with caster mounts.

Accurate Data Collection and Analysis

Multi-channel Squirrel data acquisition records temperature and time; 5 sensors are located at the 4 corners and in the middle for analysis by PC.

Model Selection

Dimensions h×d×w (mm)

1030 x 1020 x 1020

Temperature Range Cold Side

                            Heating            

+5°C to 30°C

Room temperature +5°C to 50°C

Stability ℃

 ±0.5

Display Method

Digital

Display Resolution ℃

1

Built-in temperature/time recording sensor

Standard

Working area mm

760 x 760

Power 230V W

2050

EMC (radiation standard)

Class A

Weight kg

43

Contact Hongke to help you solve your problems.