- Home
- Technical Products
Enterprise Cloud IT Solutions
Test Measurement
Industrial Measurement
- Solutions
Enterprise Cloud IT Solutions
Test Measurement
- Resource Center
- About Us
EN
TrackSense Pro - Conductivity and Temperature Sensor

Conductivity and Temperature Sensors
The conductivity and temperature sensors have a conductivity range of 0 to 200 µS/cm and a temperature range of 0 to +100 °C. The conductivity measurements are suitable for control/monitoring of industrial processes and for validation of the washing and disinfecting process in hospitals regulated by EN ISO 15883:2009. The data logger can be used in the pharmaceutical, medical/hospital, fermentation, food and beverage, sugar, petroleum, chemical and power plant industries.
The high-quality wireless TrackSense Pro data logger is made of high-strength stainless steel and offers high-end technology for stable and highly accurate measurements in different thermal processes.
The TrackSense Pro DataCORDER series is equipped with an interchangeable sensor option that unlocks multiple measurement parameters:
✓ Temperature
✓ Pressure
✓ Conductivity
✓ Relative Humidity
✓ Vacuum
✓ Vapor penetration
The DataCORDER can be easily activated and read by multiple readout stations and combined with the Sky Module via wireless communication to obtain real-time data.
- Technical Parameters
Sensors with this logger configuration: | Conductivity and Temperature Sensors | Recorders with this sensor configuration: | LAN 3G |
---|---|---|---|
Conductivity range: | 0 to 200 μS/cm | Working temperature: | +5 to +50°C |
Measurement Principle: | Conductivity/Resistance | Surface material: | 316 Liter Stainless Steel |
Sensor element: | Conductivity / Pt1000 | Diameter of the logger: | 25mm |
Connection material: | Peek (FDA compliant) | Recorder length: | 44mm |
Dimensions L x D: | 37 mm x 25 mm / 13 mm | With battery weight: | 48g |
Immersion depth: | 0.1 μS/cm | Memory capacity: | 120,000 data points/60,000 sample values |
Conductivity accuracy: | ± 1 μS/cm or ± 2.5 % of reading, whichever is worse. | Minimum sampling rate: | 1s |
IP Class: | IP67 | Maximum sampling rate: | 24h |
Temperature range: | 0 to +100°C* | Maximum startup delay: | 14 days |
Temperature accuracy: | ± 0.05 °C | Benan: | Ex II1GD Ex ia IIC T3 Ga, -50 °C ≤ Tamb ≤ +105 °C |
*Conductivity sensors are not for vapors. Designed for sterilization, but can be autoclaved at +121 °C. | Time accuracy: | ±5s/24h | |
Battery: | TSP Standard Battery | ||
Please note: If the equipment is to be used in an ATEX environment, the special conditions for safe use specified in section 17 of the ATEX Certificate must be taken into account. |
Sensor Options
4 Bar Pressure Sensor
6 Bar Pressure Sensor
Pressure and Rigid Temperature Sensor
Rigid Temperature Sensor
Bowie Dick Sensor
Double Rigid Temperature Sensor
Double Semi Flexible High Temperature Sensor
Double Semi Flexible Temperature Sensor
Internal Temperature Sensor
Rigid High Temperature Sensor
Rigid Multipoint Temperature Sensor
Rigid and SmartFlex Temperature Sensor
Rugged Flexible Temperature Sensor
Semi Flexible High Temperature Sensor
Semi Flexible Temperature Sensor
Vacuum Sensor
Automarker
Conductivity and Temperature Sensor
Double SmartFlex Temperature Sensor
High Range Conductivity and Temperature Sensor
Relative Humidity and Temperature Sensor
SmartFlex Temperature Sensor
Temperature Thermocouple Sensor
Key Benefits and Features
- One Logger - Multiple Sensor Options
- Conforms to 21 CFR Part 11
- Real-time data of SKY module
- User-friendly verification software
- Works with E-Val Pro thermocouple system

Software
ValSuite software is the industry's leading verification and calibration software and is highly credited with countless reporting options, impeccable data integrity, user calibration options and data analysis capabilities.
The software is used to run all of ELLAB's hardware and can combine various measurement systems into a unified study. In addition to its wide range of features, ValSuite complies with FDA 21 CFR Part 11 and is designed according to the GAMP guidelines. In addition, the software automatically generates PDF reports with clear pass/fail indications and can be run on stand-alone PCs or networked computers.
✓ Complies with FDA 21 CFR Part 11
✓ safe and reliable
✓ Windows Security Options
✓ Compatible with Windows 10
✓ Available in multiple languages
✓ Suitable for various applications
✓ Multiple Reporting Options
- One software platform for all Ellab devices
- Combine TrackSense data logger and E-Val Pro wired thermocouple system in the same session
- Automatic PDF report generation with clear pass/fail indication
- Runs on standalone PC or network
Applications

Cleaner and sterilizer
Sterilizers are used in medical and pharmaceutical applications to prepare items for future autoclaving (e.g. surgical instruments for removing residues such as blood and proteins) or sterilizing (semi-sterilizing) items for later use.