- Home
- Technical Products
Enterprise Cloud IT Solutions
Test Measurement
Industrial Measurement
- Solutions
Enterprise Cloud IT Solutions
Test Measurement
- Latest Articles
- About Us
EN
PCAN-Micromod Series Digital Mining Module
General purpose CAN bus data acquisition IO module
Function Overview:
- The PCAN-MicroMod series modules are analog/digital data acquisition modules that support the CAN bus.
- Various PCAN-MicroMod motherboards are available for use in equipment, industrial engineering, and the automotive industry. Optional evaluation boards simplify extending custom board functionality and development.
- The PCAN-MicroMod can be configured using compatible Windows software. In addition to easy I/O mapping to CAN IDs, there are function blocks for data processing. Configurations created on a computer are sent via the CAN bus to the PCAN-MicroMod, which then operates as an independent CAN node. Multiple modules can be independently configured on the CAN bus. Configuring the device requires a PEAK CAN card, available with USB, PCIe, and miniPCIe interfaces.
Configuring the device requires a PEAK CAN card with USB, PCIe, or miniPCIe interfaces.
Product Selection Guide
| Product Name | Model version 1 | Analog Version 2 | Digital Version | Hybrid version 1 | Hybrid version 2 | Hybrid version 3 | PCAN-MIO | |
| Analog input | Channel | 8 | 8 | 2 | 3 | 8 | 6 | |
| Range of voltage | 0 - 5 V | +/- 10V | 0 - 5 V | 0 - 4.1 V | 0 - 4.1 V | 0-10V | ||
| Resolution | 10bit | 16bit | 10bit | 10bit | 10bit | 10bit AD | ||
| Rate of sampling | 1KHz | 2KHz | 1KHz | 1KHz | 1KHz | |||
| Analog output | Channel | 4 | 4 | 2 | 2 | |||
| Range of voltage | 0 - 10 V | 0 - 10 V | 0 - 10 V | 0 - 10 V | ||||
| Resolution | 8bit PWM | 12bit DAC | 16bit PWM | 10bit DA | ||||
| Current of output | 15mA | 20mA | 15mA | 20mA | ||||
| Digital input | 8 channels for pull-up or pull-down, 5-18V voltage difference | 6 | 2 | 8 | 8 | |||
5-18V difference of voltage | 5-18V difference of voltage | 5-18V difference of voltage | ||||||
| Low-pass | Low-pass | Low-pass | Low-pass | |||||
| Digital output | 5-channel, Switching on low or high level | 2 | 1 | 8 | 8 | |||
| Fast Low-Level Switching, max. 55 V, 0.75 A | Fast Low-Level Switching, max. 55 V, 0.75 A | High and low drive can be switched | 2-channel can be used as PWM | |||||
| Temperature Input | 2, NTC | 2, NTC | ||||||
| Frequency Input | 4,0-10kHz | |||||||
| PWM/Frequency Output | 4 | |||||||
| Number of CAN channels | 1 | 1 | 1 | 1 | 1 | 1 | 2 | |
Accessories Package Solution
Item No. : PCAN-MicroMod Series Digital Mining Module - Analog 1(IPEH-002204/002207) / Digital 1(IPEH-002200/002201)
Mix 1(IPEH-002201/002203) / PCAN-MIO(IPEH-002187-/A/SET/ASET)
CAN Card (Optional Interface)
- 120Ω Terminator Resistor - Male to Female (Quantity Optional)
- DB9 Cable Board
Please consult Hongke sales staff for the price of accessories set
CAN Card (Optional Interface)
- 120Ω Terminator Resistor - Male to Female (Quantity Optional)
- DB9 Cable Board
- Power Supply (12V)
- DB9 Adapter (Female-Female/Male-Female/Male-Male)
- DB9 Serial Cable (Multi-Head)
Please consult Hongke sales staff for the price of accessories set
CAN Card (Optional Interface)
- 120Ω Terminator Resistor - Male to Female (Quantity Optional)
- DB9 Cable Board
- Power Supply (12V)
- DB9 Adapter (Female-Female/Male-Female/Male-Male)
- DB9 Serial Cable (Multi-Head)
- DB9-OBD Cable (2/4)
- DB9 to 4mm Banana Plug Adapter
Please consult Hongke sales staff for the price of accessories set
Frequently Asked Questions
Technical support and paid services to drive your project to the limit.
HONGKE I/O modules are designed with harsh industrial environments in mind. Core products such as PCAN-MicroMod FD series motherboards and PCAN-MicroMod FD DR CANopen Digital 1 modules are housed in aluminum or high-strength plastic housings and support DIN rail mounting.
They also support extended operating temperature ranges (typically -40°C to +85°C) and feature wide voltage inputs (e.g., 8-30V DC) and I/O protection circuits. For example, the PCAN-MicroMod FD DR module provides power isolation up to 500V.
The above design ensures stable and reliable operation under vibration, high and low temperatures, and power fluctuations.
The highly modular design of the HTC solution provides an all-in-one data acquisition solution.
The core product PCAN-MicroMod FD / PCAN-MicroMod is a programmable I/O core board with integrated multiple analog inputs and digital I/O functions.
It can also be equipped with specialized modules for different functions, for example:
- Analog signal: PCAN-MicroMod FD Analog 1 (16-bit high precision ADC)
- Digital Signal: PCAN-MicroMod FD Digital 1/2 (High Side/Low Side Out)
- Temperature Signal: MU-Thermocouple1 CAN FD Thermocouple Module (8 channels)
- Through the core board + dedicated module approach, you can flexibly build a data collection node that meets your actual needs.
HONGKEI offers the MU-Thermocouple1 CAN FD thermocouple module, designed for multi-channel temperature measurement.
Key features include:
- 8 independent thermocouple inputs
- Supports J / K / T thermocouple types.
- Measurement range up to +1200°C
- Accuracy up to ±0.2%
With built-in signal conditioning and cold-end compensation, the module can output temperature data directly through the CAN FD bus with good interference immunity, which is very suitable for applications such as multi-point temperature monitoring of battery packs.
The I/O modules are based on CAN / CAN FD bus communication.
A decentralized data acquisition system can be achieved by connecting multiple I/O modules through a single CAN twisted pair cable.
The PCAN-MicroMod series, for example, can be configured with up to 32 module nodes in the same network.
This structure can be significantly reduced:
- Number of Cables
- System Weight
- Wiring Complexity
- Installation Costs
Expansion of the system is also possible by simply adding new modules to the bus.
No complex underlying programming is required.
Avision provides Windows graphical configuration tools such as PCAN-MicroMod FD Configuration.
User interface:
- Maps the input channel to the specified CAN ID.
- Setting a Data Byte
- Configuring Scaling and Offset
Once configured, it can be downloaded to the module and run as a standalone CAN node, automatically converting and transferring data.
This can be achieved with PCAN-Gateway series gateways such as PCAN-Ethernet Gateway FD DR.
The framework is as follows:
I/O Module → CAN Network → Gateway → In-vehicle Ethernet / WLAN
The gateway can be realized by converting CAN messages to TCP / UDP protocol for transmission:
- In-vehicle data sharing
- Remote Monitoring
- CarCloud
- Centralized Equipment Management
The system supports a variety of standardized integration methods:
- DBC file (standardized description format for CAN signals)
- CANopen / CANopen FD Industrial Agreement
- J1939 Agreement (via PCAN-Explorer plug-in)
Therefore, it can be easily integrated with SCADA systems, CANoe, PCAN-Explorer, and other host computer software.
You can.
With PCAN-MicroMod FD Configuration, you can configure the module's built-in function blocks, for example:
- Conditional Trigger CAN Report
- Simulation overrun alarm
- Simple Logic Control
Some products (e.g. PCAN-MIO) also support PPCAN-Editor 2, which can be realized:
- Mathematical Computing
- Logical Judgment
- Curve Control
This enables local pre-processing or simple control functions.
PCAN-GPS series modules (e.g. PCAN-GPS Pro FD) can be used.
The device is integrated:
- GNSS receivers (GPS / Beidou, etc.)
- Triaxial Accelerometer
- Gyroscope
- Magnetometer
All data is processed internally and output via the same CAN FD channel, enabling time-synchronized recording of vehicle motion and bus data.
Avision offers Evaluation Board evaluation kits.
An example is the PCAN-MicroMod FD Evaluation Board:
- Lead all I/O pins out to the wiring terminal
- Integrated USB / RS-232 interface
- Supports rapid circuit testing and functional verification
Evaluation kits also typically include a PCAN-USB FD interface and cables for an out-of-the-box prototyping environment.
Professional technical support from HONGKEI to help you succeed in your project.
HongKe's PEAK MicroMod / CAN FD module series are designed to provide flexible and efficient in-vehicle bus communication and control solutions, supporting multi-channel CAN / CAN FD data transmission and analog signal acquisition. The products include digital inputs and outputs, analog inputs, thermocouple sensing, and general purpose modules that can be quickly integrated into embedded systems, industrial automation, and test platforms. Whether you need to realize high-speed signal conversion, accurate data acquisition, or multi-node communication control, HongKe's PEAK MicroMod series provides highly stable and compatible solutions to meet your needs at all stages of development, testing and mass production.