- Home
- Technical Products
Enterprise Cloud IT Solutions
Test Measurement
Industrial Measurement
- Solutions
Enterprise Cloud IT Solutions
Test Measurement
- Resource Center
- About Us
EN
多功能數據記錄儀 – 4路熱電偶輸入和以太網端口的溫度計

M1200
通用型數據記錄器,有 4 個輸入端,用於輸入熱電偶 K、J、S、B、T、N。
The multifunction data logger can be permanently installed on an Ethernet network or used as a portable device.
A traceable calibration certificate to EN ISO/IEC17025 is included.
The Multi-Function Data Logger is a battery-powered data logger capable of measuring and recording sensor and electrical values through its inputs.
The multifunctional data logger can be connected to an Ethernet network. Measurements can be viewed on a browser, saved and downloaded for subsequent analysis.
Warranty: 3 years
- Technical Parameters
- Delivery list
Measurement parameters
Temperature
Temperature Sensor - Thermocouple K, N
Measurement range: -200 to +1300 °C
Measurement accuracy: ±0.3% of measured value with 1.5°C deviation
Resolution: 0.1 °C
Temperature Sensor - Thermocouple J
Measurement range: -200 to +750 °C
Measurement accuracy: ±0.3% of measured value with 1.5°C deviation
Resolution: 0.1 °C
Temperature Sensor - Thermocouple S
Measurement range: 0 to +1700 °C
Measurement accuracy: ±0.3% of measured value with 1.5°C deviation
Resolution: 0.1 °C
Temperature Sensor - Thermocouple B
Measurement range: 100 to +1800 °C
Measurement accuracy: ±0.31 TP3T of the measured value in the range +300 to +1800 °C with 1 °C deviation
Resolution: 0.1 °C
Temperature Sensor - Thermocouple T
Measurement range: -200 to +1300 °C
Measurement accuracy: ±0.3% of measured value with 1.5°C deviation
Resolution: 0.1 °C
DC Voltage:
Measurement range: -60 to +140 mV; -18 to +18 mV
Measurement accuracy: ±100 µV; ±20 µV
Resolution: 0.1 µV
General Technical Data
Operating temperature: -10 to +60 °C
Channels: 4 external temperature probes
Total storage capacity: 1,000,000 values in non-cyclic recording mode; 600,000 values in cyclic recording mode
Recording interval: adjustable from 1 second to 24 hours
Display and alarm updates: every 10 seconds
Data logging modes: Non-cyclic - stops logging when the memory is full; cyclic - the earliest data is overwritten with new data after the memory is full
Available Temperature Units: Celsius, Fahrenheit
Communication Interface: Ethernet, USB, RS232
Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK.
Alarm Protocol: Email
Power: AC adapter 230Vac/5Vdc (required for Ethernet interface)
Battery life: 3 - 4 weeks
Protection level: IP20
Dimensions (without connector): 178 x 95 x 37 mm without connection cable
Weight (including battery): approx. 380 g
Warranty: 3 years
- M1200
- Operator's Manual
- Traceable calibration certificate
- 3 AA type rechargeable batteries
- Power supply
- USB-C cable
- Wall Mount Bracket
- Free analysis software COMET Vision
Delivery without external probe